What Temperature Should a Hot Water Cylinder Be Set At?
Set a hot water cylinder to store water at 60°C. That is the temperature Health and Safety Executive guidance uses for controlling Legionella in stored hot water, and it is what cylinder and immersion thermostats are normally set to from the factory. The water should then reach the taps at 50°C or more within about a minute of running. Going lower saves very little and lets bacteria multiply in the tank. Going much higher speeds up limescale on the coil and element, raises the scald risk at the taps, and brings the cylinder closer to the point where its safety devices take over. If the water at a bath or basin is too hot at 60°C storage, the fix is a blending valve at the outlet, not a lower cylinder setting.
The numbers that matter
Three temperatures do almost all the work here. Legionella bacteria multiply in water between roughly 20 and 45 degrees, and they do not survive at 60 degrees and above. Stored hot water held at 60 degrees stays out of the growth range. Water arriving at the taps at 50 degrees or more within a minute tells you the pipework is not holding lukewarm water either.
The problem zone is a cylinder turned down to 45 or 50 degrees to save money, or a large cylinder where only the top gets properly hot and the bottom sits lukewarm for days. Both leave a volume of warm water sitting still, which is the combination the bacteria need. It is also the usual reason hot water smells like rotten eggs, since the bacteria that make that smell like the same lukewarm conditions.
- Stored hot water: 60°C
- At the hot tap, within about a minute of running: 50°C or more
- Legionella growth range: roughly 20 to 45°C
- Bath outlet in a new dwelling under Building Regulations: no more than 48°C
Where the temperature is actually set
It depends on what heats the cylinder, and many homes have two settings that both matter.
On an indirect cylinder heated by a boiler, the cylinder thermostat decides the stored temperature. It is either strapped to the side of the tank or sits in a pocket, usually with a dial marked in degrees. When the water reaches the setting it tells the motorised valve to close and the boiler stops heating the cylinder. The boiler also has its own flow temperature, and it has to be comfortably higher than the cylinder setting, or the cylinder will never reach 60 however long it runs.
On an immersion heater, the rod thermostat inside the element has a small adjuster behind the plastic cap, normally set at 60. On a direct cylinder with two elements, each has its own. Unvented cylinders often have an immersion thermostat with a separate safety cut-out that has to be reset by hand if it ever trips.
A combi boiler has no stored water, so there is no cylinder to set. The hot water temperature is a dial on the boiler, and Legionella in stored water is not the same concern.
The immersion adjuster sits next to live terminals. Isolate the immersion at the switch and fused spur before removing the cap, or leave it to an engineer.
Why turning it down is a false economy
The saving from a lower cylinder setting is small. You heat the water through fewer degrees and lose a little less through the insulation, but it amounts to pennies a day on a typical household. Against that, water sitting at 45 degrees is warm enough for bacteria to multiply and nowhere near hot enough to kill them.
It also tends not to work as intended. A cylinder set lower delivers less usable hot water, because you mix less cold with it at the tap. Households that turn the thermostat down often find they run out of hot water sooner and end up heating it more often. If the running cost is the worry, the guide to immersion heater running cost covers the changes that do save money.
Why turning it right up is not the answer either
In London the main cost of a very hot cylinder is limescale. The higher the water temperature, the faster calcium comes out of hard water onto the hottest surfaces, which are the boiler coil and the immersion element. A cylinder run at 70 degrees in a hard water area furs its coil noticeably faster than the same cylinder at 60, and a furred coil cannot be cleaned in place. We cover that process in hard water and hot water cylinders in London.
The second cost is scalding. Water from a 60 degree cylinder is already hot enough to scald quickly, especially for young children and older people. At 70 degrees and above the risk rises steeply. The third is that you are running closer to the settings of the safety devices, which are there for failures, not for daily use.
What happens when the temperature goes too high by itself
An unvented cylinder has layers of protection above its normal setting. The control thermostat should stop heating at 60 or so. If it fails, a high limit cut-out stops the heat source. If that fails too, the temperature and pressure relief valve opens at around 90 to 95 degrees and discharges water through the tundish, which is the last line of defence against the stored water boiling.
If your hot water is suddenly scalding, the water is steaming at the taps, or hot water is running into the tundish, one of those layers has already failed. Switch off the immersion and the boiler and read our page on hot water cylinder overheating before doing anything else. That is not a thermostat to adjust; it is a fault to find.
Scalding at the taps: blending valves, not lower storage
Keeping the stored water at 60 and delivering it to the outlet cooler are two separate jobs, and a thermostatic mixing valve is what joins them up. It blends hot and cold to a fixed outlet temperature, and a good one shuts off the hot if the cold supply fails. New build baths are required to have one, and they make sense wherever there are young children, older people or anyone with reduced sensation.
Do you need a thermostatic mixing valve? Our guide covers where they are required, TMV2 against TMV3, and what servicing they need.
Heat pumps and the weekly high temperature cycle
Heat pumps heat water efficiently at lower temperatures, often below 60 degrees. To keep the cylinder safe, heat pump systems are normally set to run a periodic pasteurisation cycle, often weekly, that lifts the whole tank to 60 degrees or more, using the heat pump, the immersion or both. If you have a heat pump cylinder, check with whoever commissioned it that the cycle is set, running and timed for when the tank is full rather than empty.
Landlords: the Legionella duty
Landlords of residential property have a legal duty to assess the risk from Legionella in the water system and control it. For most ordinary flats and houses with a cylinder, HSE guidance is that the assessment can be simple and does not usually require water testing. Keeping stored hot water at 60 degrees, avoiding long lengths of little used pipework and making sure a cylinder that has stood empty between tenancies is heated and flushed before anyone moves in are the practical controls.
The wider set of obligations, from repair timescales to annual servicing of unvented cylinders, is covered in landlord hot water responsibilities.
How to check your own cylinder in five minutes
Run the hot tap nearest the cylinder for one minute and hold a kitchen or cooking thermometer in the stream. You want 50 degrees or more. Then do the same at the furthest hot tap in the property. If the near tap is fine and the far one takes much longer, the pipe run is long and poorly insulated, which is a pipework issue rather than a cylinder one.
If the nearest tap will not reach 50 degrees after the cylinder has had its full heating time, something is not holding temperature: a thermostat set low or failed, a boiler flow temperature set too low, a failed element, or a furred coil. Water not getting hot works through those causes in order.
If you want it checked properly, call 020 4652 5111. On an unvented cylinder the temperature and safety controls are checked as part of an unvented cylinder service, and an engineer holding the unvented qualification will set and test them.
Questions we get asked
- What temperature should a hot water cylinder be set at?
- 60°C for the stored water. That controls Legionella bacteria, and hot water should then reach the taps at 50°C or more within about a minute of running. Most cylinder and immersion thermostats are set to 60 from the factory.
- Is 50 degrees warm enough for a hot water cylinder?
- Not for storage. At 50 degrees Legionella bacteria are not reliably killed and water at the bottom of the tank can sit cooler still. 50 degrees is the target at the tap, not in the cylinder.
- Can I set my hot water cylinder to 65 or 70 degrees?
- You can, but in hard water areas like London the coil and immersion element scale up faster, and the scald risk at the taps rises. 60 degrees is the balance point. If you need more usable hot water, a larger or faster recovering cylinder is the better fix.
- Why is my hot water hotter than the cylinder setting?
- Usually because a thermostat has failed and the heat source is not switching off. If the water is scalding, steaming or discharging into the tundish, switch off the immersion and the boiler and have the cylinder checked. That is a safety fault, not a setting.
- Does a combi boiler need to be set to 60 degrees?
- No. A combi boiler heats water as it passes through and stores none, so stored water Legionella control does not apply in the same way. The hot water temperature on a combi is a comfort setting.
- Do landlords have to test for Legionella?
- Landlords have to assess and control the risk, but for most ordinary homes HSE guidance does not require water testing. Keeping stored hot water at 60 degrees and flushing a cylinder and pipework that have stood unused are the practical controls.
- How do I stop hot water scalding children if the cylinder is at 60?
- Fit a thermostatic mixing valve at the bath or basin. It keeps the stored water at a safe 60 while delivering the outlet at a lower fixed temperature, and cuts the hot if the cold fails. Lowering the cylinder setting instead trades a scald risk for a bacteria risk.